VK Series

Kanaga’s VK Series


Features:

  • Mechanically actuated Diaphragm
  • High Precision Balls and Seal Rings for Accuracy
  • Flow adjustment by micrometer type with locking system
  • Composite GYLON/PTFE Diaphragm for long life
  • Motor driven worm shaft & Worm wheel drive
  • Liquid end material of construction in PP (Also in SS316, PVC and Teflon on request)
  • Light weight Aluminium alloy body
  • Modular design occupying less foot print
  • Steady state accuracy +/-2%
  • Repeatability +/-3%
  • Turn Down Ratio 10:1

Motor Details

  • Standard: 3 Phase, 415 V, TEFC, 50Hz, Class 'F', 1440 RPM, IP55
  • Optional: Flame proof @ request / availability

Specifications

MODEL MAX CAPACITY LPH MAX PRESSURE KG/CM2 END CONNECTION




VK
30
35
50
100
10
5
8
5


LDPE Tubing 1/2" x 3/8"
200
300
400

5

1" BSP (M)

Features

  • Mechanically actuated diapharagm
  • High precision balls and seal rings for accuracy.
  • Manual flow control, adjustable through stroke length adjustable knob.
  • Composite GYLON/PTFE Hypalon diapharagm for long life
  • Motor driven worm shaft & Worm wheel drive.
  • Liquid end material of construction in PP (Also in SS316, PVC and Teflon on request)
  • Light weight aluminium alloy body
  • Modular design occupying less foot print
  • Steady state accuracy +/-2%
  • Repeatability +/-3%
  • Turn down ratio 10:1

Installation & Operation

  • Fix the pump securely in a safe location away from sunlight, sources of heat and other dangerous environs, allowing for a maximum suction lift of 1 metre only.
  • Cut the supplied tubing into a 1 metre section and connect one of its ends to the suction of the pump and other to the foot value.
  • Ensure the suction tubing is held straight within the chemical storage tank.
  • Connect the rest of the required length of tubing to the discharge side of the pump head.
  • Connect the NRV in a vertical position in the required injection point
  • Position the discharge tube above the pump head in a safe direction
  • Plug in the mains chord of the pump to a single phase 230vAc, 5amp socket.
  • Wait for the pump to prime into the head.
  • As soon as the liquid starts to flow out of the tube turn off the pump promptly now connect the fully primed tube into the NRV.
  • Turn the pump on again and check for leaks in all areas.
  • Now finally adjust the speed buttons as per your dosing requirement.

Specifications

MODEL MAX CAPACITY LPH MAX PRESSURE KG/CM2 END CONNECTION
VK
30
35
50
10
5
8
LDPE Tubing 1/2" x 3/8"
100 5 LDPE Tubing 1/2" x 3/8"
200
300
400
5 1" BSP (M)