Kanaga’s VC Series
Features:
- Gland less and leakage proof Diaphragm pump
- Proven Electronic Pulser Circuitry
- Efficient Electromagnetic Solenoid Assembly
- Excellent Proportional Control
- Corrosion resistant F.R.P. Housing
- Teflon faced Hypalon DIAPHRAGM
- Accuracy +/- 3%
- 20:1 Turn Down Ratio
- Suction lift of 1 Metre
- Liquid End Options PP, PVC, SS and Teflon
Standard Accessories
- L.D.P.E. Tubing
- Spring loaded injection check valve & Foot valve
Optional Accessories
- H.D.P.E. Chemical Storage Tank
- F.R.P. Chemical Storage Tanks Low Level Float Switch
Installation & Operation
- Fix the pump securely in a safe location away from sunlight, sources of heat and other dangerous environs, allowing for a maximum suction lift of 1 metre only.
- Cut the supplied tubing into a 1 metre section and connect one of its ends to the suction of the pump and other to the foot value.
- Ensure the suction tubing is held straight within the chemical storage tank.
- Connect the rest of the required length of tubing to the discharge side of the pump head.
- Connect the NRV in a vertical position in the required injection point
- Position the discharge tube above the pump head in a safe direction
- Plug in the mains chord of the pump to a single phase 230vAc, 5amp socket.
- Wait for the pump to prime into the head.
- As soon as the liquid starts to flow out of the tube turn off the pump promptly now connect the fully primed tube into the NRV.
- Turn the pump on again and check for leaks in all areas.
- Now finally adjust the speed buttons as per your dosing requirement.
Specifications
MODEL |
MAX CAPACITY LPH |
MAX PRESSURE KG/CM2 |
END CONNECTION |
VC |
5 10 15 |
15 10 6 |
LDPE Tubing 3/8" x 1/4" |
30 75 100 |
4 2 1 |
LDPE Tubing 1/2" x 3/8" |