Features:
- Gland less and leakage free teflon faced Diaphragm
- Electromechanical solenoid driven by robust electronic pulser
- Excellent dosage linearity
- Adjustable injection frequency
- Special G.F.P.P. Long life housing
- Compact in all means
- Low Power Consumption
Standard Accessories
- L.D.P.E. Tubing
- Spring loaded injection check valve & Foot valve
Optional Accessories
- H.D.P.E. Chemical storage Tank
- F.R.P. Chemical Storage Tanks with Low Level Float Switch
Installation & Operation
- Fix the pump securely in a safe location away from sunlight, sources of heat and other dangerous environs, allowing for a maximum suction lift of 1 metre only
- Cut the supplied tubing into 1 Metre length and connect one of its ends to the suction of the pump and other to the foot valve
- Ensure the suction tubing is held straight within the chemical storage tank
- Connect the rest of the required length of tubing to the discharge side of pump head
- Connect the NRV in a vertical position in the required injection point
- Position the discharge tube above the pump head in a safe direction
- Plug in the Mains Chord of the pump to a single phase 230vAC, 5Amps Socket
- Wait for the pump to prime into the head.
- As soon as the liquid starts to flow out of the tube turn off the pump promptly now and connect the fully primed tube into the NRV
- Turn the pump on again and check for leaks in all areas
- Now finally adjust the speed buttons as per your dosing requirement
Specifications
MODEL |
MAX CAPACITY LPH |
MAX PRESSURE KG/CM2 |
END CONNECTION |
CD/CDMP |
5 10 |
4 1 |
LDPE Tubing 3/8" x 1/4" |
Features:
- Gland less and leakage free Teflon Faced Diaphragm
- Electromechanical solenoid driven by robust electronic mictroprocessor pulser
- Excellent dosage linearity
- Fine adjustable facility of stroke speed & stroke length upto 1spm, max 99 spm
- Special G.F.P.P. Long life housing
- Provision for low level cut-off
- Compact in all means
- Low Power Consumption
Standared Accessories
- L.D.P.E. Tubing
- Spring loaded injection check valve & Foot valve
Optional Accessories
- H.D.P.E. Chemical Storage Tank
- F.R.P. Chemical Storage Tanks with Low Level Float Switch
Installation & Operation
- Fix the pump securely in a safe location away from sunlight, sources of heat and other dangerous environs, allowing for a maximum suction lift of 1 metre only
- Cut the supplied tubing into 1 Metre length and connect one of its ends to the suction of the pump and other to the foot valve
- Ensure the suction tubing is held straight within the chemical storage tank
- Connect the rest of the required length of tubing to the discharge side of pump head
- Connect the NRV in a vertical position in the required injection point
- Position the discharge tube above the pump head in a safe direction
- Plug in the Mains Chord of the pump to a single phase 230vAC, 5Amps Socket
- Wait for the pump to prime into the head.
- As soon as the liquid starts to flow out of the tube turn off the pump promptly now and connect the fully primed tube into the NRV
- Turn the pump on again and check for leaks in all areas
- Now finally adjust the speed buttons as per your dosing requirement
Specifications
MODEL |
MAX CAPACITY LPH |
MAX PRESSURE KG/CM2 |
END CONNECTION |
CD/CDMP |
5 10 |
4 1 |
LDPE Tubing 3/8" x 1/4" |