VA Series


Features:

  • Gland less and leakage free teflon faced Diaphragm
  • Electromechanical solenoid driven by robust electronic pulser
  • Excellent dosage linearity
  • Adjustable injection frequency (100 SPM)
  • Adjustable volume displacement via stroke length knob.
  • Special G.F.P.P. Long life housing
  • Teflon faced Hypalon DIAPHRAGM for long lasting service
  • Wide range of liquid ends - PP/PVC/SS316/PTFE
  • Low Power Consumption

Standard Accessories

  • L.D.P.E. Tubing
  • Spring loaded injection check valve & Foot valve

Optional Accessories

  • H.D.P.E. Chemical Storage Tank
  • F.R.P. Chemical Storage Tanks with low level Float Switch

Installation & Operation

  • Fix the pump securely in a safe location away from sunlight, sources of heat and other dangerous environs, allowing for a maximum suction lift of 1 Metre only
  • Cut the supplied tubing into a 1 Metre length and connect one of its ends to the suction of the pump and other to the foot valve
  • Ensure the suction tubing is held straight within the chemical storage tank
  • Connect the rest of the required length of tubing to the discharge side of the pump head
  • Connect the NRV in a vertical position in the required injection point
  • Position the discharge tube above the pump head in a safe direction
  • Plug in the Mains Chord of the pump to a single phase 230vAC, 5Amp Socket
  • Wait for the pump to prime into the head
  • As soon as the liquid starts to flow out of the tube turn off the pump promptly now and connect the fully primed tube into the NRV
  • Turn the pump on again and check for leaks in all areas
  • Now finally adjust the speed buttons as per your dosing requirement

Specifications

MODEL MAX CAPACITY LPH MAX PRESSURE KG/CM2 END CONNECTION


VA/VA MP
1
2
5
6
12
12
10
5
4
1


LDPE Tubing 3/8" x 1/4"

Features:

  • Gland less and leakage free teflon faced Diaphragm
  • Electromechanical solenoid driven by robust electronic microprocessor pulser
  • Excellent dosage linearity
  • Fine adjustment of stroke speed & stroke length upto 1spm, max 99 spm
  • Adjustable volume displacement via stroke length knob.
  • Special G.F.P.P. Long life housing
  • Prevision for Low voltage / High voltage cut off
  • Integrated low level cut-off switch (Optional)
  • Teflon faced Hypalon DIAPHRAGM for long lasting service
  • Low Power Consumption
  • Wide range of liquid ends - PP/PVC/SS316/PTFE

Standard Accessories

  • L.D.P.E. Tubing
  • Spring loaded injection check valve & Foot valve

Optional Accessories

  • H.D.P.E. Chemical Storage Tank
  • F.R.P. Chemical Storage Tanks with Low Level Float Switch

Installation & Operation

  • Fix the pump securely in a safe location away from sunlight, sources of heat and other dangerous environs, allowing for a maximum suction lift of 1 metre only.
  • Cut the supplied tubing into a 1 metre section and connect one of its ends to the suction of the pump and other to the foot value.
  • Ensure the suction tubing is held straight within the chemical storage tank.
  • Connect the rest of the required length of tubing to the discharge side of the pump head.
  • Connect the NRV in a vertical position in the required injection point
  • Position the discharge tube above the pump head in a safe direction
  • Plug in the mains chord of the pump to a single phase 230vAc, 5amp socket.
  • Wait for the pump to prime into the head.
  • As soon as the liquid starts to flow out of the tube turn off the pump promptly now connect the fully primed tube into the NRV.
  • Turn the pump on again and check for leaks in all areas.
  • Now finally adjust the speed buttons as per your dosing requirement.

Specifications

MODEL MAX CAPACITY LPH MAX PRESSURE KG/CM2 END CONNECTION


VA/VA MP
1
2
5
6
12
12
10
5
4
1


LDPE Tubing 3/8" x 1/4"